Some scientific research about 76-60-8

As far as I know, this compound(76-60-8)Product Details of 76-60-8 can be applied in many ways, which is helpful for the development of experiments. Therefore many people are doing relevant researches.

The preparation of ester heterocycles mostly uses heteroatoms as nucleophilic sites, which are achieved by intramolecular substitution or addition reactions. Compound: 3,3-Bis(3,5-dibromo-4-hydroxy-2-methylphenyl)-3H-benzo[c][1,2]oxathiole 1,1-dioxide( cas:76-60-8 ) is researched.Product Details of 76-60-8.Suckey, Melissa M.; Benza, Donald W.; DesJardins, John D.; Anker, Jeffrey N. published the article 《Upconversion spectral rulers for transcutaneous displacement measurements》 about this compound( cas:76-60-8 ) in Sensors. Keywords: spectral ruler autofluorescence optical encoder scattering implanted medical device; X-ray excited optical luminescence; autofluorescence; fluorescence; implanted medical device; optical encoder; optical scattering; sensing through tissue; spectral ruler. Let’s learn more about this compound (cas:76-60-8).

We describe a method to measure micron to millimeter displacement through tissue using an upconversion spectral ruler. Measuring stiffness (displacement under load) in muscles, bones, ligaments, and tendons is important for studying and monitoring healing of injuries. Optical displacement measurements are useful because they are sensitive and noninvasive. Optical measurements through tissue must use spectral rather than imaging approaches because optical scattering in the tissue blurs the image with a point spread function typically around the depth of the tissue. Addnl., the optical measurement should have low background and minimal intensity dependence. Previously, we demonstrated a spectral encoder using either X-ray luminescence or fluorescence, but the X-ray luminescence required an expensive X-ray source and used ionizing radiation, while the fluorescence sensor suffered from interference from autofluorescence. Here, we used upconversion, which can be provided with a simple fiber-coupled spectrometer with essentially autofluorescence-free signals. The upconversion phosphors provide a low background signal, and the use of closely spaced spectral peaks minimizes spectral distortion from the tissue. The small displacement noise level (precision) through tissue was 2μm when using a microscope-coupled spectrometer to collect light. We also showed proof of principle for measuring strain on a tendon mimic. The approach provides a simple method to study biomechanics using implantable sensors.

As far as I know, this compound(76-60-8)Product Details of 76-60-8 can be applied in many ways, which is helpful for the development of experiments. Therefore many people are doing relevant researches.

Reference:
Indole alkaloid derivatives as building blocks of natural products from Bacillus thuringiensis and Bacillus velezensis and their antibacterial and antifungal activity study,
Preparation of Indole Containing Building Blocks for the Regiospecific Construction of Indole Appended Pyrazoles and Pyrroles